Specification parameters
Performance index | ||||||||
Conversion efficiency | 84%~90%(full load) | |||||||
Power factor | 0.9~0.99(full load) | |||||||
ppm/℃(100%RL)Temperature coefficient | 100 | |||||||
Overall dimensions | 0.75kW~5kW,1U, 1U chassis;10kW~15kW, 2-3U,2-3U chassis | |||||||
Cooling mode | Fan cooling | |||||||
Constant voltage mode | ||||||||
(20MHz)mVp-p Noise | 70 | 100 | 130 | 150 | 175 | 200 | 300 | 400 |
(5Hz-1MHz)mVrmsRipple | 30 | 35 | 35 | 35 | 65 | 65 | 65 | 65 |
V Max. compensation voltage | ±3V | |||||||
(100%RL)Input adjustment rate | 5×10-4(10kW Below 10kW) | 1×10-4(10kW Above 10kW) | ||||||
(10%~100%RL) Load adjustment rate | 5×10-4(10kW Below 10kW) | 3×10-4(10kW Above 10kW) | ||||||
8h(100%RL) Stability | 1×10-4(7.5~80V), 5×10-5(100~250V) | |||||||
Constant current mode | ||||||||
(20MHz)mVp-p Noise | 70 | 100 | 130 | 150 | 175 | 200 | 300 | 400 |
(5Hz~1MHz)mVrmsRipple | 30 | 35 | 35 | 35 | 65 | 65 | 65 | 65 |
(100%RL) Input adjustment rate | 1×10-4(10kW Below 10kW) | 5×10-4(10kW Above 10kW) | ||||||
(10%~100%RL) Load adjustment rate | 3×10-4(10kW Below 10kW) | 5×10-4(10kW Above 10kW) | ||||||
8h(100%RL)DCCT Stability | 4×10-4(25A~200A), 1×10-4(250A~500A) |
FAQ
1. Can you identify your own products? Of course, we have our own LOGO, process and product traceability, so we can accurately identify our products.
2. What testing equipment does your company have? We have various accurate testing equipment, such as withstand voltage meter, megameter, multimeter, clamp meter, oscilloscope, thermal imager, etc.
3. Which countries and regions have your products been exported to? Our products have been exported to the United States, Britain, France, South Korea, Russia and other countries.
4. Does your company have its own brand? Of course, we have been developing our own brand – INJET since its establishment.
Product detail pictures:
Related Product Guide:
Our pursuit and enterprise goal is to "Always satisfy our customer requirements". We keep on to establish and style and design outstanding top quality goods for both our outdated and new prospects and realize a win-win prospect for our clientele likewise as us for Short Lead Time for Medical Isolation Power Supply System - PDA series programmable DC power supply – Injet , The product will supply to all over the world, such as: Argentina, Kuwait, Kazakhstan, Our solutions have national accreditation requirements for qualified, good quality products, affordable value, was welcomed by individuals all over the world. Our products will continue to improve inside the order and appear forward to cooperation with you, Definitely should any of those goods be of curiosity to you, be sure to letus know. We'll be satisfied to supply you a quotation up on receipt of the detailed needs.
Write your message here and send it to us